Size |
A
(Max.)
|
B |
C
Nom
|
D
Nom |
Max. Operating Pressure
-20oF
to 650oF
for each design
1/16 in. Corrosion Allowance |
Est. Wt.
(Max.) |
PDF |
|
3 |
10 ¾ |
30 |
3 |
 |
375; 540; 1200 |
322 |
|
|
3 ½ |
10 ¾ |
34 |
3 ½ |
380; 540; 1200 |
375 |
|
|
4 |
12 ¾ |
38 |
4 |
325; 450; 1200 |
558 |
|
|
5 |
12 ¾ |
46 |
5 |
325; 446; 1200 |
717 |
|
|
6 |
12 ¾ |
54 |
6 |
194 |
192 |
|
|
6 |
13 ¼ |
68 |
6 |
249; 847; 1076 |
607 |
|
|
8 |
14 |
78 |
8 |
174 |
260 |
|
|
8 |
15 ¼ |
92 |
8 |
214; 731; 931 |
941 |
|
|
10 |
16 |
106 |
10 |
138 |
444 |
|
|
10 |
17 ¼ |
120 |
10 |
188; 554; 820 |
1441 |
|
|
12 |
18 |
126 |
12 |
123 |
617 |
|
|
12 |
19 ¼ |
140 |
12 |
167; 413; 574;
794; 890 |
1881 |
|
|
14 |
20 |
146 |
14 |
100 |
786 |
|
|
14 |
21 ¼ |
161 |
14 |
151; 299; 446;
717; 804 |
2387 |
|
|
16 |
22 |
166 |
16 |
88 |
985 |
|
|
16 |
23 ¼ |
180 |
16 |
137; 273; 406;
473; 654; 733 |
2935 |
|
|
|
Note: Dimensions
are applicable to both standard and reduced inlet
silencers. Standard silencers do not include
diffusers. Dimensions C and D are equal on standard
silencers. Data on larger sizes available upon
request. |
Dimensions in inches
Pressure in PSIG |
|